Involved in improvements of the treatment of viscous or with particulates products, ACTINI SA has fitted its exchangers with tubes modified in geometry.
Specific geometries
• Corrugated
• Multilobe • Multitubulaire
Operating principle
•
In laminar flow (number of Reynolds < 2100), the heat exchange rates are far much lower than in a turbulent one.
•
The tubes with modified geometry have been designed in order to increase the global exchange rate and for a "core" treatment and homogenization.
•
In these tubes, the exchange surface is indeed higher in comparison with the volume of treated product.
Main assets
•
Improvement in the thermal efficiencies (up to 30%)
•
Treatment "in the middle" (no cold vein).
•
Geometries particularly appropriate to heat- sensitive products containing particules or very viscous.
•
Longer production period
•
Cleaning of the exchangers without dismounting it (design avoiding stagnant areas and preferential circuits, thus giving them perfect hygienic properties)
•
30% reduction of the machine size
Comparison between cylindrical and Trilobe Tubes
Type
SIB05
SIB06
UHT07
UHT09
UHT18
UHT24
UHT32
Debit
Viscosity 1 cp at 20°C
Viscosity 10 000 cp at 8°
500 l/h
100 l/h
2 000 l/h
400 l/h
4 000 l/h
800 l/h
7 000 l/h
2 000 l/h
15 000 l/h
3 500 l/h
22 000 l/h
6 000 l/h
30 000 l/h
10 000 l/h
Diam.
Interieur
In mm
12,00
18,00
23,00
36,00
48,50
60,50
72,80
Longueur
In mm
1200
2000
3000
3000
3000 ou 6000
3000 ou 6000
6000
ACTINI GROUP